Measure the system—not the label
Run the flow test at the machine inlet.
A pump may advertise enough flow in isolation and still fall short after a small tank outlet, loaded filter, long hose, restrictive connector or height change. Build the same path you intend to use, then measure where the supply hose meets the pressure washer.
- 01Use the lowest normal tank level
That is often the more demanding part of the working range. Keep the vehicle level and the tank safely secured.
- 02Include every restriction
Fit the production outlet, valves, filter, connectors and full hose length before testing.
- 03Measure flow over time
Collect into a marked vessel. Litres collected ÷ seconds × 60 gives litres per minute.
- 04Check pressure separately
A bucket test gives flow, not inlet pressure. Use a suitable gauge or competent installer when the manual states a pressure requirement.
The manual remains the authority
Stored-water operation is model-specific.
Some machines support suction from an open container only with a particular priming method, filter, check valve, hose or maximum lift. Others require a pressurised inlet. A result here cannot transfer one manufacturer's instructions to another model.
- Find the exact model manual and record its inlet flow, inlet pressure and suction or priming instructions.
- Ask the manufacturer in writing when a required figure or tank-fed arrangement is unclear.
- Re-test after changing the filter, hose, fittings, pump setting or tank position.
- Use the 12V water pump selector to turn a confirmed shortfall into a flow-and-pressure duty point.
- Run the payload check: each litre of carried water adds roughly one kilogram before the tank and fittings.